Two inspections, one building
Owners of Maywood rentals sometimes ask us to "do a Level 2 on everything" because it sounds thorough, or to "just do the basic one" because it sounds cheap. Neither is a plan. A building usually needs the routine visual check on most fireplaces and the camera run on a few, each picked for a reason. This post compares the two from a landlord's side of the ledger and explains how Whitley Chimney Care decides which line each unit gets.
Side by side
| Item | Routine visual check | Camera run of the flue |
|---|---|---|
| Price per fireplace | $55 | $395 |
| What it reaches | Room side, lower flue under a light, reachable stack top | All of that plus the flue interior on video |
| Typical use | The yearly record for a unit in steady use | Sales, relines, fuel changes, damage, unexplained signs |
| What you keep | A page with photos | A page with photos and the flue footage |
The visual check, from a landlord's chair
NFPA 211, the fire code document that chimney work in this country leans on, calls the lightest inspection a Level 1. It suits a fireplace that has been working the same way and is expected to keep doing so. On our visits the tech checks the brick or panels of the firebox, the damper, the hearth and the gap to the mantel, the lower flue under a strong light, and the top of the stack where the roof allows.
For a rental, this is the record you will need most often. It shows the owner, the insurer and the next manager that each fireplace was looked at this year, by whom, and what was found. At $55 a line it costs little to repeat every year, and repeating it is the point: a crack that grows between one year's photos and the next is a finding in its own right.
The camera run, from the same chair
What a Level 2 adds is what the room and the roof cannot show: the inside of the flue from the throat to the top, on video, plus any parts of the chimney reached through an attic or crawl space. At $395 per flue it is not a yearly habit for every unit. It is the right line when:
- a unit or the whole building is being sold, refinanced or handed to a new manager
- a flue is changing fuel, wood to gas, or getting a new liner or insert
- the building went through a chimney fire, a strong quake or a roof leak near the stack
- the visual check found a stain, a crack or a draft problem it could not explain from below
- a tenant reports smoke in the room, or a smell from the fireplace when it is not in use
A third level exists, where finish or brick is opened to reach concealed parts. We only suggest it when camera footage gives a reason, and in rentals that is uncommon.
How we sort a building
On a first visit to a Maywood building we usually book every fireplace on the visual-check line. On the day, any unit that shows a reason for the camera gets a note on its page saying so, with the reason spelled out. Some owners have us run the camera there and then; others book it for later. Either way the owner sees the reason before paying for the deeper look.
There are exceptions at booking. If you already know a unit is being sold, is switching to gas or had a fire, tell us and that unit is booked as a camera run from the start.
Why "Level 2 on everything" rarely pays
On a building where every fireplace is in steady use and nothing has changed, a camera run on each flue costs roughly seven times what the visual checks would, and it usually tells you little more about flues that have behaved the same way for years. That money is better kept for the units that show a reason, and for the repairs those units may need.
Why "basic only" can cost more
The opposite mistake is turning down the camera when a unit has given a reason. A cracked tile hidden above the throat lets heat and gases reach places they should not. A rental with a known stain and no follow-up is a hard thing to explain after a loss, to a tenant or to an insurer. Next to that, the camera run is the cheap part of the story.
Where gas units fit
Gas fireplaces get the same choice. Most need only the visual check, with the pilot, burner, glass and vent end looked at on the same visit. A gas unit vented into an old masonry flue, or one that went in as a conversion without a new liner, is a good candidate for the camera. Cleaning of the burner and glass is a separate line; see gas fireplace cleaning.
Booking the right mix
Use the form at the top of this page with the address, the fireplace count and any unit you already know needs the camera, with the reason. We confirm the mix in writing before the visit, unit by unit. Details of each inspection are on the chimney inspection and Level 2 inspection pages, and managers planning several buildings can see the yearly plan on the property manager and HOA page.
A note on records
Whichever line a unit gets, the page looks the same: unit, room, fuel, findings, photos, next step and the date. Camera units add the footage. Keeping one layout across both inspections is what lets a manager compare a building from year to year without reading two different kinds of report.
Closing
The right mix is a short list, not a blanket rule. When you want that list drawn up for your building, start on the contact page.
Every Fireplace on One Record
Whitley Chimney Care visits each unit on your list, climbs the roof once for all the stacks and files a page per fireplace. Visits are routed from Maywood to Huntington Park, Bell, Cudahy, Montebello and further across the county.